Manifold protection device: open circuit
,over heat, SGFP;
High power factor and low electromagnetic
disturbance;
Wide load range and even brightness;
Use only indoor;
NG.A104FL With high performance and
reasonable price,use pull chain switch or midway switch,especially
suitable for small neon sign.
NG.A108FTwith adjustable dimmer in a wide
arrangement and even brightness.
NG.A104FL
NG.A108FT
Model
NG.A104FL
NG.A108FT
Input
120V 60Hz 0.36A Max.
120V 60Hz 0.63A Max.
Output
4kV 30mA
8kV 30mA
Weight(kg)
0.73
0.85
Packing
20pcs 17kg
20pcs 19.5kg
Packing size (mm)
558×235×273
742×257×280
Diameter (mm)
7
8
9
10
11
12
13
15
7
8
9
10
11
12
13
15
Gas pressure (mmHg)
18
17
15
13
12
11
10
9
18
17
15
13
12
11
10
9
Load length in feet(clear or red neon)
6
7
7
9
10
12
15
17
12
13
15
19
22
26
29
33
Load length in feet(mercury/argon)
7
8
8
11
12
14
16
19
14
15
18
23
26
31
33
40
Notes :
1.All
listed values are indicative and represent an average. Values can significantly
vary due to filling pressure, temperature, high voltage cable length,
electrode type and sign material;
2.Deduct 1 foot
for each Pair of electrodes from above load length figures;
3.Footage
for mercury filled tubes based on operation at 4℃(40°F)or above.Deduct 25% of
footage for operation below 4℃(40°F).
Product Characteristic
Compliance with UL standard UL2161;
Manifold protection device: open circuit
,over heat, SGFP;
High power factor and low electromagnetic
disturbance;
Exposed type grounding output, easy to
connect ground for small neon signs;
With pull-chain switch and UL standard plug, excellent for small neon signs;
Use only indoor.
NG.A206GL
NG.A410EL
Model
NG.A206GL
NG.A410EL
Input
120V 50/60Hz 0.7A
120V 50/60Hz 0.9A
Output
6kV 30mA 34kHz
10kV 30mA 32kHz
Min loading(D12mm
mercury/argon)
2m
4m
Weight(kg)
0.8
0.9
Packing
20pcs 18.5kg
20pcs 21.5kg
Packing size(mm)
742×257×280
742×257×280
Diameter(mm)
7
8
9
10
11
12
13
15
7
8
9
10
11
12
13
15
Gas pressure(mmHg)
18
17
15
13
12
11
10
9
18
17
15
13
12
11
10
9
Load length in feet(clear or red neon)
7
8
9
11
13
16
17
19
16
18
21
25
28
31
34
39
Load length in feet(mercury/argon)
8
9
11
12
15
18
20
23
18
21
25
30
33
37
40
48
Notes :
1.All listed values are indicative and
represent an average. Values can significantly vary due to filling
pressure, temperature, high voltage cable length, electrode type and
sign material;
2.Deduct 1 foot for each Pair of electrodes from above load length
figures;
3.Footage for mercury filled tubes based on operation at 4℃(40°F)or
above.Deduct 25% of footage for operation below 4℃(40°F);
4.The loading shall not exceed the max. value and the minimum value
listed in the table when using, the minimum loading of products with
different diameter can be calculated according to the max. value.