Position : Home >>> Products >>> NEON POWER Series >>> UL Series

 

Product Characteristic

 

Compliance with UL standard UL2161;

Manifold protection device: open circuit ,over heat, SGFP;

High power factor and low electromagnetic disturbance;

Wide load range and even brightness;

Use only indoor;

NG.A104FL With high performance and reasonable price,use pull chain switch or midway switch,especially suitable for small neon sign.

NG.A108FTwith adjustable dimmer in a wide arrangement and even brightness.

 
 
 

  NG.A104FL


  NG.A108FT

 
Model NG.A104FL NG.A108FT
Input 120V 60Hz 0.36A Max. 120V 60Hz 0.63A Max.
Output 4kV 30mA 8kV 30mA
Weight(kg) 0.73 0.85
Packing 20pcs 17kg 20pcs 19.5kg
Packing size (mm) 558×235×273 742×257×280
Diameter (mm) 7 8 9 10 11 12 13 15 7 8 9 10 11 12 13 15
Gas pressure (mmHg) 18 17 15 13 12 11 10 9 18 17 15 13 12 11 10 9
Load length in feet(clear or red neon) 6 7 7 9 10 12 15 17 12 13 15 19 22 26 29 33
Load length in feet(mercury/argon) 7 8 8 11 12 14 16 19 14 15 18 23 26 31 33 40

Notes :

1.All listed values are indicative and represent an average. Values can significantly vary due to filling pressure,  temperature, high voltage cable length, electrode type and sign material;

2.Deduct 1 foot for each Pair of electrodes from above load length figures;

3.Footage for mercury filled tubes based on operation at 4℃(40°F)or above.Deduct 25% of footage for operation below 4℃(40°F).

 

Product Characteristic

 

Compliance with UL standard UL2161;

Manifold protection device: open circuit ,over heat, SGFP;

High power factor and low electromagnetic disturbance;

Exposed type grounding output, easy to connect ground for small neon signs;

With pull-chain switch and UL standard plug, excellent for small neon signs;

Use only indoor.

 
 
  NG.A206GL

 
  NG.A410EL

 
Model NG.A206GL NG.A410EL
Input 120V 50/60Hz 0.7A 120V 50/60Hz 0.9A
Output 6kV 30mA 34kHz 10kV 30mA 32kHz
Min loading(D12mm mercury/argon) 2m 4m
Weight(kg) 0.8 0.9
Packing 20pcs 18.5kg 20pcs 21.5kg
Packing size(mm) 742×257×280 742×257×280
Diameter(mm) 7 8 9 10 11 12 13 15 7 8 9 10 11 12 13 15
Gas pressure(mmHg) 18 17 15 13 12 11 10 9 18 17 15 13 12 11 10 9
Load length in feet(clear or red neon) 7 8 9 11 13 16 17 19 16 18 21 25 28 31 34 39
Load length in feet(mercury/argon) 8 9 11 12 15 18 20 23 18 21 25 30 33 37 40 48
Notes :
1.All listed values are indicative and represent an average. Values can significantly vary due to filling pressure, temperature, high voltage cable length, electrode type and sign material;
2.Deduct 1 foot for each Pair of electrodes from above load length figures;
3.Footage for mercury filled tubes based on operation at 4℃(40°F)or above.Deduct 25% of footage for operation below 4℃(40°F);
4.The loading shall not exceed the max. value and the minimum value listed in the table when using, the minimum loading of products with different diameter can be calculated according to the max. value.

Electronic Equipment Factory of Guangzhou Salvage  all rights reserved  Email:jinshi@gseef.com [金时电子厂]QQ ONLINE:406374148